allinstock.net

Gestra NRG16-40

Gestra

Il codice del prodotto: NRG16-40
Produttori: Gestra
Confirmed Rating: ☆☆☆☆☆ (3.8)
Rating Count: 13670

Contattate il nostro team per la marca Gestra il codice NRG16-40 per ulteriori informazioni sul prodotto. Compilate anche un modulo di preventivo online. Ti risponderemo al più presto.
PLEASE MAIL TO: info@allinstock.net

Datasheets for Gestra NRG16-40

Description for Gestra NRG16-40

Description The level electrodes NRG 1...-40 work according to the conductivity measurement principle and detect the min. level in electrically conductive liquids:  One level alarm with one switchpoint Use level electrode NRG 1...-40 in combination with level switch NRS 1-40 or NRS 1-40.1 and/or other system components. The NRG 1...-40 in conjunction with its associated control equipment constitutes a water level limiter with periodic self-testing routine (SMART function) in accordance with TRD 604, sheet 1 and 2 and EN regulations. The level data are transferred from the electrode NRG 1...-40 to the control unit via a CAN bus using the CANopen protocol.Function The electrode operation is based on the conductive measuring principle using the electrical conductivity for signalling liquid levels. Some liquids are conductive, which means that they allow an electric currrent to flow through them. For the safe functioning of this device a minimum conductivity of the liquid to be monitored is required. The conductivity measurement method can detect two conditions: electrode rod submerged or exposed, meaning switchpoint reached (or exceeded) or not yet reached. Before installation, the electrode rod must be cut to length to give the required low-level alarm and effect the consequent cut-out of the burner circuit. The system incorporates an additional electrode that provides automatic monitoring of the electrical resistance path between the measuring electrode and the earth. When the measured value falls below the admissible resistance value the burner shutdown is endorsed by interruption of the burner protection circuit. At regular intervals, the level electrode NRG 1...-40 sends a data telegram to the controller NRS 1-40. The data transfer is effected by means of a CAN bus according to DIN ISO 11898 adopting the CANopen protocol. One controller type NRS 1-40 can be used for two level electrodes NRG 1...-40 (low-level limiter arrangemant).

Latest Comments for Gestra NRG16-40


Altri prodotti consigliati Gestra


Gestra BK45 DN25 FL-PN-40B1 7081500 Kondenststop
Gestra MK45-2 + MK35/12 DIN15-25 Spare Part Kit
Gestra MK45-2 DN25 FL-PN40B1 (160) 7251501 Steam Trap
Gestra 3661800 MPA 46 DN50 Blowdown Valve
Gestra 5045F025 steam trap BK45
Gestra BA210 BLOWDOWN VALVE
Gestra BB 25C PN 25 check valve
Gestra BK28DN15 PN100 Steam Trap
Gestra BK29 DN25 PN160 1.7335 KONDENSTOP
Gestra RK 41 DN20 PN16 Non-Return Valve
Gestra MK35/12 Thermostatic Steam Traps
Gestra LRGT 16-2 G1
Gestra KS92-1 266154402 Universal Controller
Gestra LRG16-40 G1 PN40 conductivity measurement
Gestra LRGT 16-1 G1 PN40 PT1000 4-20 MA L:300MM
Gestra LRGT 16-1 G1 PN40 PT1000 4-20MA
Gestra LRGT 16-1 PN40 COMPACT ELECTRODE
Gestra LRGT 16-2 KART
Gestra LRGT 16-2 PN40
Gestra LRGT16-2 #3773146
Gestra LRR 1-40 24V electronic board
Gestra MB14 DN25 PN16 Non-Return Valves
Gestra MK35/31 1.0460 /A105 3/8
Gestra MK45-2 PN40 DN25 KONDENSTOP
Gestra MK45-2 PN40DN15 KONDENSTOP
Gestra NGRS 15-1 Compact System for Level Monitoring
Gestra NRG 16-50 PN40 G3/4
Gestra NRG 19-50 PN160 G3/4 ELEKTROD
Gestra NRG16-50 PN40 level electrode
Gestra NRGS 16-50 PN40 G3/4 1000MM SPECTOR MODUL
Gestra NRGS15-1 L=1000MM ELEKTROT
Gestra NRGS15-1 PN25
Gestra NRGT 26-1 230V AC 1000MM
Gestra NRGT 26-1 G 3/4
Gestra NRGT26-1 PN40 G 3/4 Level transmitter
Gestra NRS 1-50 100-240VAC LEVEL SWITCH